Fortis Roofing Farnborough 01252 596302 Get a quote

Roof Windows & Skylights Installation in Farnborough

New openings, like-for-like swaps and leak repairs

We measure the opening, check the flashing and the tiles or slates around it, and tell you whether a repair, a straight swap or a new window makes sense.

Get a free quoteCall 01252 596302

  • Photos and measurements
    of your roof
  • One written
    price
  • Repairs, re-roofs
    and emergencies
  • 10-year workmanship
    guarantee

Find us on Google

Roof window in a brown tile roof on a flint and brick house

Signs a roof window needs attention

  • Drips or stains on the ceiling below
  • Condensation running down the inside glass
  • Misting trapped between the two panes
  • A sash that sticks or will not close
  • Lifted flashing or cracked tiles beside the frame

Windows and rooflights we fit

White-clad dormer loft conversion on a tile roof

Roof windows

Opening windows in a pitched roof slope, sealed by a flashing kit.

Grey single-ply flat roof with roof lanterns and a crane beyond

Rooflights

Glazed units for flat roofs, usually mounted on a raised upstand.

Single-storey rear extension with two roof windows above glass doors

Sun tunnels

A reflective tube carrying daylight from the roof to a ceiling.

Roof window services in Farnborough and nearby

  • New roof windows
  • Like-for-like replacement
  • Flashing kit repairs
  • Glass and seal repairs
  • Flat roof rooflights
  • Blinds and controls

Repair, swap or new opening?

Repair

The window is sound, but a seal, hinge or flashing has failed.

Swap

The frame or glazing has had its day, and the opening stays the same size.

New opening

You want daylight where there is none, so rafters are cut and trimmed.

Roof windows, the figures

What the regulations ask of a roof window

Heat-loss limits, planning conditions, escape sizes and lead codes from the approved documents, the planning order and manufacturers, read one by one against the window in your own roof.

Chapters of this guide and the figure each one turns on
No.ChapterThe figure it turns on
01Swap like for like, or cut a new openingTable 4.2: new or replacement windows
02How much heat a roof window may loseRoof windows: 1.4 or Band B
03Planning rules for a window in the slope0.15 metres beyond the slope
04Flashing kits, leaks and repairsCode 4 lead for flashings and soakers
05Loft conversions and escape windows0.33m² minimum openable area
06Conservation areas and Article 4 near FarnboroughNine conservation areas across Rushmoor

Chapter 01 of 06

Swap like for like, or cut a new opening

The rules that frame any roof window job

  • Table 4.2AD L limits for new or replacement roof windows
  • Reg 2(3)Roof windows and rooflights are not thermal elements
  • Class COther alterations to a house roof, normally permitted
  • 15 June 2022Date AD L 2021 took effect in England
Source: Approved Document L, Volume 1, 2021 edition incorporating 2023 amendments; Building Regulations 2010 reg 2(3) and GPDO 2015 Sch 2 Pt 1 on legislation.gov.uk; accessed 28 October 2026

A roof window is an opening window built into the slope of a pitched roof, the type many people call a Velux after the best-known maker. A rooflight, often called a skylight, sits on a flat roof or a very low slope, usually on a raised kerb called an upstand. A sun tunnel is a tube with a small dome on the roof and a diffuser in the ceiling below, carrying daylight down to a landing or bathroom. Each is fitted and sealed differently, and the regulations treat roof windows and rooflights separately. We fit and repair all three on homes and small commercial buildings across Farnborough, Aldershot, Ash Vale, Fleet, Farnham and Camberley.

Replacing a roof window in the same opening

Where an existing window is worn out, the simplest job is a like-for-like replacement: a new window of the same size in the same opening. The rafters are already trimmed around the hole, the linings are in place, and the tiles or slates around it only need lifting far enough to fit a new flashing kit. Many swaps can be done from inside the room, working out through the opening, though a steep or high slope can still call for scaffolding.

A replacement still has to meet Part L. Approved Document L Table 4.2 covers new or replacement elements in existing homes, and its window row includes roof windows. So an old single-glazed or early double-glazed unit is swapped for one that meets the current limit, which chapter 02 sets out. Regulation 2(3) of the Building Regulations 2010 also leaves roof windows and rooflights out of the definition of a thermal element, so changing one is not treated as renovating the roof.

Cutting a new opening in the roof

A new roof window is a bigger job. Battens and tiles are stripped back, the rafter or rafters in the way are cut, and the opening is trimmed: framed with extra timbers so the load the cut rafter carried passes to the ones either side. That is structural work, so we check the trimming detail with your building control body before any rafter is cut. Inside, the opening is lined and the plaster made good; outside, the tiles are cut and refitted around the new flashing.

On a house, a new roof window is normally permitted development under Class C, the planning class for other alterations to a roof, subject to the conditions in chapter 03. Flats have no permitted development rights, and a conservation area or a listed building adds steps of its own. Our guide to replacing a Velux window like for like or as a new opening sets the two routes side by side, and our pitched roofing service covers the tiles and battens around the frame.

Chapter 02 of 06

How much heat a roof window may lose

Maximum U-values in Approved Document L 2021, in W/(m²K): lower means less heat lost

  • Rooflight, new or replacement2.2
  • Roof window, new or replacement1.4Or Window Energy Rating Band B
  • Thermal element once upgraded0.7
  • Upstand built on site0.35
  • Retained roof, improved value0.16
Source: Approved Document L, Volume 1, 2021 edition incorporating 2023 amendments, Tables 4.2 and 4.3 and para 4.13; accessed 28 October 2026

A U-value is the rate heat passes through one square metre of a wall, roof or window for every degree between its warm side and its cold side. Smaller numbers mean better insulation. Glass loses heat faster than an insulated roof, so the limits for windows sit well above those for the roof around them, and the chart shows how wide that gap is.

The limits a new roof window has to meet

Approved Document L, the guidance that goes with Part L of the Building Regulations, sets limiting values in its Table 4.2 for elements fitted new, or as replacements, in existing homes. A roof window takes the window figure: a U-value of 1.4, or a Window Energy Rating of Band B as a minimum. The note on that row says the window figure includes roof windows. A rooflight on a flat roof has its own, looser limit of 2.2, and an upstand built on site to carry it is capped at 0.35.

The two lowest bars are about the roof rather than the glass. When a loft is converted, the existing roof is a retained element, and Table 4.3 sets a threshold of 0.35 and an improved value of 0.16. Paragraph 4.13 allows a smaller upgrade where the full one cannot be done technically or functionally, or would take longer than 15 years to pay back, and puts a general ceiling of 0.7 on a thermal element once it has been upgraded. These tables apply until 24 March 2027, when the 2026 edition of Approved Document L takes over and renumbers them 3.2 and 3.3.

Rooflights on flat roofs and extensions

Flat roofs on rear extensions and garages take rooflights rather than roof windows. A rooflight sits on an upstand so the flat roof covering, whether felt, EPDM (a synthetic rubber membrane) or GRP (a fibreglass laminate), can be dressed up its sides and sealed below the frame. That junction is where a flat-roof rooflight tends to let water in, so the covering and the upstand are checked together, along with the falls that carry water away from the kerb.

A roof window from a mainstream maker comes with its U-value or energy rating on the data sheet, and that is the figure we check against the table before ordering. Better glazing also gives a warmer inside pane, which cuts both heat loss and the cold surface that condensation forms on. That is the energy efficiency case for replacing an old unit, and it often matters more to comfort than the bill. Our guide to roof window U-values and Part L goes further into the tables and the 2027 changes.

Chapter 03 of 06

Planning rules for a window in the slope

Class C conditions for a roof window on a house
RuleWhat it saysWhere it comes from
Class CAlterations to a house roof are normally permitted development.GPDO 2015, Schedule 2, Part 1
C.1(b)Nothing may protrude more than 0.15 metres beyond the plane of the original slope.GPDO 2015, Class C
C.2 glazingA window on a side roof slope must be obscure-glazed.GPDO 2015, Class C
C.2 openingFixed shut, unless the parts that open are more than 1.7 metres above the floor.GPDO 2015, Class C
FlatsNo permitted development rights.GPDO 2015, article 2
Listed homesClass C still applies; listed building consent is needed for works affecting character.LBCA 1990, section 7
Source: GPDO 2015 Schedule 2 Part 1 and article 2; LBCA 1990 s7; legislation.gov.uk, accessed 28 October 2026

Planning permission and Building Regulations are separate tests, and a roof window can touch both. Planning is about how the house looks and how a change affects its surroundings. On a house, the General Permitted Development Order grants permission in advance for many small changes, and Class C covers alterations to a roof that are not dormers or other enlargements. A roof window falls under it. The rules below are the national ones; local designations come later, in chapter 06.

The conditions that come with Class C

Class C carries conditions, and the table lists them. Nothing may protrude more than 0.15 metres beyond the plane of the original roof slope, measured at right angles to its surface. Roof windows are made to sit close to the slope, and a recessed fit sets the frame lower still, which counts on a front slope that faces the street.

The side-slope condition is the one that catches people out. Where a roof window goes into a slope forming a side elevation of the house, it must be obscure-glazed, whatever its height. It must also be non-opening, unless its opening parts are more than 1.7 metres higher than the room's floor. The height relaxes only the opening rule. A window on a side slope over a landing or bedroom therefore needs frosted or patterned glass in every case, and we order it that way.

When Class C does not cover the work

Flats have no permitted development rights, so a roof window on a block or a house split into flats needs planning permission. Rushmoor's own guidance says flats need planning permission for any work other than like-for-like replacement, or anything that might alter how the building looks. A listed house keeps its Class C rights, but listed building consent is needed for works affecting its character, so a new opening in a listed roof goes to the council's conservation team first. An Article 4 direction can also withdraw permitted development rights across a defined area, and chapter 06 covers where that touches roofs near Farnborough.

Building Regulations are the other half. A replacement window has to meet the Part L limits in chapter 02, and a new opening means cutting rafters, so we take the structural detail to your building control body. Around Farnborough, Aldershot and Fleet that is the Hart and Rushmoor Building Control Partnership, run from Rushmoor's council offices in the town, on 01252 398715. In Farnham it is Waverley Borough Council's own team, and in Guildford the council runs its own service too. Our post on planning permission for a skylight walks through the planning side in plain steps, with examples.

Chapter 04 of 06

Flashing kits, leaks and repairs

The lead codes, fixing rule and slate pitch around a frame

  • Code 3Royston lists it for soakers only
  • Code 4Lightest code listed for flashings, soakers and dormers
  • AD C para 6.8Each sheet, tile and section of roof fixed appropriately
  • 20° minimumBS 5534 pitch for natural slate, per Cupa Pizarras
Source: Royston Lead cast lead sheet brochure; Approved Document C, 2013 edition; Cupa Pizarras citing BS 5534; accessed 28 October 2026
Flashing matched to covering
The kit type is matched to the tile or slate profile around the frame.

Water that gets past a roof window usually comes in around the frame, not through the glass. The part that keeps it out is the flashing: a set of shaped aluminium or lead-faced pieces made for one window size and one kind of roof covering. Fitted properly, it carries water over the head of the window, down its sides and out onto the tiles below, while the side pieces tuck under the tiles either side.

Why the roof covering decides the kit

A profiled tile, such as a deep interlocking concrete tile, needs a kit with a soft, deep apron that can be dressed into the waves of the tile below. A flat covering, such as natural slate or a plain clay tile, uses a kit with stepped soakers, small pieces slipped under each course, so the window lies flat with the slates. A kit made for a different covering leaves gaps that wind-driven rain finds. Natural slate also has a minimum pitch of 20° under BS 5534, as Cupa Pizarras reports it, which matters when a window goes into a low rear slope.

On older or listed roofs, lead is sometimes dressed by hand around the frame instead. Royston Lead lists Code 3 for soakers only, and Code 4 as the lightest code for flashings and dormers. Approved Document C wants every sheet, tile and section fixed appropriately, and the tiles and slates cut around a new frame are no exception. Our lead roofing and lead work service covers hand-dressed lead in more depth.

Repairs: glass, hinges, seals and blinds

Not every fault means a new window. Water on the inside face of the glass is usually condensation: warm, damp air from a bathroom or bedroom meeting the coldest surface in the room. Opening the vent bar, better room ventilation and a warmer glazed unit all help. Misting between the two panes is different, because the seal around the sealed unit has failed, and on many windows the glazed unit or the whole sash can be changed without touching the frame or flashing. Hinges, handles and opening gear wear, and a sash that will not close tight lets in draughts and rain. Blinds can be added to an existing window once its size and model are known.

Lead codes

Code 3Soakers only, in Royston Lead's listing
Code 4Flashings, soakers and dormers as well
Source: Royston Lead cast lead sheet brochure

Routine maintenance helps too: clearing leaves and moss from the head of the flashing, where they hold water against the frame, and checking the tiles beside it after a storm. A head gutter packed with debris sends water sideways beneath the neighbouring tiles, and that shows inside as a stain beside the frame rather than below it. Our guides on why a Velux window leaks and how flashing kits work go further into both.

Chapter 05 of 06

Loft conversions and escape windows

Escape window sizes and the loft roof figure, as published
RequirementFigureSource
Escape window openable areaAt least 0.33m²AD B Vol 1, para 2.10
Opening height and widthAt least 450mm eachAD B Vol 1, para 2.10
Bottom of the openable areaNo more than 1100mm above the floorAD B Vol 1, para 2.10
Escape windows count forStoreys within 4.5m of the groundAD B Vol 1, para 2.5
Loft roof, improved U-value0.16AD L Vol 1, Table 4.3
Source: Approved Document B, Volume 1, 2019 edition incorporating later amendments; Approved Document L, Volume 1, Table 4.3; accessed 28 October 2026

Roof windows are the usual way to bring daylight into a loft conversion without building a dormer, and a loft can add a room without building outwards. A converted loft is a new storey, though, and it brings fire escape and insulation rules with it as well as structure. The table sets out the published figures for both.

Escape windows and the stair

Approved Document B deals with getting out of a house in a fire. An escape window needs an openable area of at least 0.33m², must be at least 450mm high and 450mm wide, and the bottom of the openable part must be no more than 1100mm above the floor. Escape windows only count for storeys within 4.5m of the ground. A loft on a two-storey house usually sits above that height, so a loft conversion usually needs a protected stair: a stairway enclosed in fire-resisting construction. The approved document also allows alternatives, including sprinkler protection to open-plan areas, so the stair and the windows are settled together with building control.

A roof window sold as an escape or egress window opens wide enough to meet those sizes, usually with a top-hung or side-hung sash rather than a centre-pivot one. Where a window is meant to serve as an escape route, its position matters as much as its size, because the sill height is measured from the finished floor of the loft, not the joists. Our guide to escape roof windows for lofts explains the options.

Benefits of installing a roof window in a loft

The roof around the windows has to be insulated too. Table 4.3 of Approved Document L sets an improved U-value of 0.16 for a roof kept as a retained element in a loft conversion, with the payback relaxation in paragraph 4.13. In practice that means insulation between and under the rafters, with the window linings insulated and sealed so the cold frame does not become a place where condensation gathers.

Sill height from finished floor
Window positions are marked against the finished loft floor before any rafter is cut.

The gains are plain enough. Natural light comes in from above rather than across from the neighbours, an opening sash at high level lets warm air out of the room on a summer evening, and the loft space gains a window without changing the outline of the roof. On Farnborough streets, from the 1950s and 1960s housing at Cove to the 1980s estates at Southwood, that can be the simplest way to use a loft. We set the window positions against the rafters, the headroom and the furniture you plan, before anything is ordered. The joists, the stair position and the head height usually settle where the windows go before the glass itself is chosen.

Chapter 06 of 06

Conservation areas and Article 4 near Farnborough

Local designations that can affect a front-slope roof window

  • NineConservation areas designated by Rushmoor Borough Council
  • 1998Hart directions covering frontage roof slopes
  • FourBasingstoke and Deane areas where roof changes need permission
  • Article 2(3)Land where Class B dormers are excluded
Source: Rushmoor Borough Council; Hart District Council; Basingstoke and Deane Borough Council; GPDO 2015 on legislation.gov.uk; accessed 28 October 2026

A conservation area does not by itself rule out a roof window. Class C, unlike the dormer rules in Class B, has no exclusion for article 2(3) land, the category that takes in conservation areas, National Landscapes and National Parks. What changes the picture is an Article 4 direction, which lets the council or the Secretary of State withdraw specified permitted development rights across a defined area, along with each council's wish to keep historic roofs looking as they did.

Article 4 directions that touch roofs locally

Rushmoor has nine designated conservation areas. Those in Farnborough include St Michael's Abbey, South Farnborough, Farnborough Street and Farnborough Hill, and in Aldershot there are Cargate and Aldershot West. In Cargate, a 2020 Article 4 direction puts window, door, chimney and flue changes under planning control wherever a highway or open space overlooks them. In Hart, the 1998 directions on many conservation areas, such as Crondall, Crookham Village and Hartley Wintney, cover alterations to the frontage of a dwelling, including works affecting a frontage roof slope. Basingstoke and Deane has made roof changes subject to planning permission in four town-centre conservation areas, where it also expects original slate and clay to stay. Guildford uses Article 4 directions in its conservation areas for frontage works and chimneys, checked address by address on its map.

Slope and covering recorded
The slope, covering and historic detail are recorded before any consent question.

For other councils, from Surrey Heath around Camberley to Waverley around Farnham, check whether an Article 4 direction applies with that council before a front-slope window is ordered. Waverley lists 44 conservation areas, among them Farnham Town Centre, designated in 1970 and extended in 1979, and Surrey Heath's nine include Upper Gordon Road to Church Hill in Camberley. Surrey's district councils are replaced by West Surrey Council and East Surrey Council on 1 April 2027, so a planning question asked before then still goes to the existing borough.

Listed roofs and conservation-style windows

On a listed house in north-east Hampshire or west Surrey, listed building consent is needed for works affecting its character, alongside any planning permission, and a new opening in a historic roof is weighed against that test. Conservation-style roof windows, with slim frames and a central glazing bar, are made for sensitive roofs and sit close to the line of the slates. Whatever the setting, we record the slope, the covering and any visible historic detail on the survey, so the planning or consent conversation starts from what is actually there. If your house sits in one of these areas, we can tell you which council to ask and what to send them, and the scaffold and access plan is set out at the same time.

The documents behind these figures

  • Approved Document L, Volume 1Conservation of fuel and power in dwellings
  • Approved Document B, Volume 1Fire safety, including escape from lofts
  • BS 5534:2014+A2:2018Slating and tiling around the frame

Find out what your roof window needs

Send us a photo of the window and the ceiling below it, and we will survey the opening, the flashing and the slope.

Get a free quote

Typical UK prices for roof window work

Typical UK prices for roof window work
JobTypical UK range
Velux window, standard mid-range (MyJobQuote)£1,100
Straightforward swap of an existing window, around £100 less (MyJobQuote)around £1,000
Roof survey, national average (MyJobQuote)around £300

Source: MyJobQuote (Velux page September 2026; roof survey page October 2026)

National guide figures, not Fortis prices. We price each roof window job as one written total once the survey is done, scaffold included.

Roof window guides and answers

Short reads on flashing kits, leaks, U-values, escape windows and flat-roof rooflights, for homeowners planning a new opening or fixing an old one.

Guide · 9 min read

Why Is My Velux Window Leaking?

Water around a roof window comes from the flashing, from condensation or from failed seals, and each has…

From survey to sealed frame

  1. Send photos of the window
  2. Survey inside and out
  3. One written price
  4. Fit, flash, finish and tidy

Roof window and skylight questions

How much does it cost to install a Velux window in Farnborough?

MyJobQuote puts a standard mid-range Velux window at £1,100, and a straightforward swap of an existing one at around £100 less. Those are national figures. The real price moves with the window size, the roof covering, whether rafters are cut, the scaffold, and the lining and plastering inside.

Can a roof window be replaced from inside the loft?

Often, yes, where the new window matches the old opening and the roof can be reached safely through it. The flashing and the tiles around it are refitted from the opening. A larger window, a high or steep slope, or awkward access can mean scaffold, and we decide that at the survey.

Why does my Velux window leak when it rains?

Water usually gets in around the frame rather than through the glass: a flashing kit made for a different covering, a cracked or lifted tile beside it, leaves packed at the head of the flashing, or a worn seal on the sash. Drips in cold, dry weather are often condensation instead. We check inside and out.

Can a roof window go into a slate roof?

Yes. Slate needs a flashing kit made for flat coverings, with soakers worked in course by course, and the slates around the frame are cut and refixed. BS 5534 gives natural slate a minimum pitch of 20°, as Cupa Pizarras reports it, so a very shallow slated slope is measured first.

Can blinds be added to a roof window that is already fitted?

Usually, yes. Blinds clip to the sash, so they are ordered for the window's model and size, which are printed on a data plate on the frame when one survives. Blackout, pleated and roller types exist, and some run on electric motors. On older windows with no plate, we measure the sash instead.

Is a sun tunnel an alternative to a roof window?

For a landing, hallway or bathroom with no outside wall, it can be. A sun tunnel carries daylight down a reflective tube from a small dome on the roof to a diffuser in the ceiling. It brings in light but cannot be opened for air, so where a room also needs ventilation a roof window does more.

Get your free roof quote

Book a roof window survey

Tell us the size and age of the window, or where the drip shows, and we will survey it.

01252 596302

10-year workmanship guarantee, in writing.

WhatsApp us